Reference Manual
00809-0100-4811, Rev DA
Section 3: Installation
January 2015
Installation
3.4.2 Installation of single lead probes in non-metallic tanks
For optimal single lead probe performance in non-metallic tanks, the probe must be mounted
with a metal flange, or screwed in to a metal sheet (d > 14 in./350 mm) if the threaded version is
used.
Figure 3-4. Mounting in Non-Metallic Tanks
Avoid disturbing Electro Magnetic Compatibility (EMC) environment near the tank. Installation
in metallic tank is recommended.
3.4.3 Mounting in still pipes/bypass pipes
In order to prevent the probe from contacting the bridle wall when replacing displacers or
installing in pipes, centering discs are available for the Rigid Single, Segmented Rigid Single,
Flexible Single, and Flexible Twin Lead probes. The disc is attached to the end of the probe and
thus keeps the probe centered in the bridle. The discs are available in stainless steel, Alloy C-276,
Alloy 400, and PTFE. See also “Mounting a centering disc for pipe installations” on page 49.
Note
It is not recommended that flexible probes are installed in bypass pipes.
Rigid single lead, segmented rigid single lead
Pipe diameter Ø2 in. (50 mm)
Inlet pipe diameter N < Ø
L 12 in. (300 mm)
Metal flange d > 2 in. /DN50
Metal sheet d > 14 in. /350 mm