Reference Manual
00809-0100-4570, Rev AC
Appendix B: Product Certifications
January 2015
Product Certifications
B.3 Hazardous locations certifications
The Rosemount 3300 Series Guided Wave Radar level and interface transmitters that have the
following labels attached have been certified to comply with the requirements of the approval
agencies noted.
B.3.1 North American certifications
Factory Mutual (FM) approvals
Project ID: 3013394
Figure B-1. Approval Labels Factory Mutual (FM)
E5 Explosion-proof for Class I, Division 1, Groups B, C and D.
Dust-ignition proof for Class II/III, Division 1, Groups E, F, and G; with intrinsically safe
connections to Class I, II, III, Div 1, Groups A, B, C, D, E, F, and G.
Temperature class T5 @+85 °C.
Ambient temperature limits: -50
°C to + 85 °C
Approval valid for HART and Modbus
®
options.
I5 Intrinsically safe for Class I, II, III, Division 1, Groups A, B, C, D, E, F, and G.
Intrinsically safe for Class I, Zone 0, AEX ia IIC T4 T
a
= 70 °C.
Temperature code T4 at 70°C max ambient.
Installation drawing: 9150077-944.
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Suitable for Class II, III, Division 2, Groups F and G.
Non-incendive maximum operating parameters: 42 V, 25 mA.
Temperature code T4A at 70 °C max ambient.
Approval valid for HART option.