Reference Manual
00809-0100-4811, Rev DA
Section 3: Installation
January 2015
Installation
3.4 Mounting considerations
Before installing the Rosemount 3300 Series Radar Transmitter, consider specific mounting
requirements, vessel characteristics, and process characteristics.
3.4.1 Process connection
The Rosemount 3300 Series has a threaded connection for easy mounting on the tank roof. It
can also be mounted on a nozzle by using different flanges.
Threaded connection
Figure 3-2. Mounting on Tank Roof Using Threaded Connection
Mounting on tank roof.
Mounting in threaded pipe.